SmartRelay 3 - LSM 3.5 SP3 Business + Prof.

This tab is split in two.

  • The Actual section shows the locking device target status. This is the status that the operator wants and which is configured in LSM but possibly may not be configured in the SREL3 ADV system yet.
  • The Target section shows the actual locking device status. This status is the last status programmed in SREL3 ADV system.

The following features can be activated, depending on the device type:

  • Pulse length
  • This where you indicate the number of seconds for the switch pulse duration (0 s to 25 s). If you enter three seconds, for example, an electric strike is released for three seconds before it locks again.
  • Audit trail
  • Access control is only available in the .ZK variant. The most recent transponder transactions are logged with the date and time.
  • Time zone management
  • Time zone control is only available in the .ZK variant. You can upload a time zone plan. Transponders are then approved or blocked according to their time zone group.
  • Log unauthorised attempts
  • Logging of unauthorised access attempts is only available in the .ZK version. If you enable this option, unauthorised transponders activations are also logged in addition to activations with authorised transponders.
  • Gateway
  • SmartRelay can be used as a gateway (see Gateway function).
  • Flip Flop
  • The relay used in the controller behaves in the same way as a monostable multivibrator (pulse generation) by default. If you enable this option, the configured pulse duration is ignored and the relay remains activated until an authorised identification medium is actuated again. This option is recommended if you wish to switch lighting, machinery and similar systems on and off.
  • IMPORTANT

    Damage due to continuous current

    Devices which are designed to generate pulses may not be suitable for continuous currents. Ensure that the power supply units and devices used, such as electric strikes, are suitable for operating with a continuous current.

  • Close-up range mode
  • Close range mode reduces the read range in the reader's B-field (see Near-field option).
  • Time switching
  • Time change-over is only available in the .ZK variant. You can upload a time zone plan. If you activate time change-over, the SREL3 ADV system can be automatically activated or blocked during the authorised or non-authorised times (in Group 5). The SREL3 ADV system will even switch automatically, depending on the setting. For example, a door can remain open automatically during the day but can only be opened with a transponder at night (see Time switch-over function).
  • Ignore activation or expiry date
  • Transponders can be given a validity date. You can enable this option if you wish the transponders to also be valid beyond this validity date.
  • Card interface
  • This option should not be changed. It allows LSM to automatically detect whether the connected reader is a hybrid reader or not during programming. If you change this option manually, detection will no longer function.