Adding the WaveNet configuration - LSM 3.5 SP3 Business + Prof.

If all requisites have been met, you can start to configure the network:

  1. LSM has been installed correctly and a network module is licensed.
  2. The CommNode server has been installed and the service launched.
  3. The CommNode server's configuration files have been created.
  4. The current version of WaveNet Manager has been installed.
  5. A communication node has been created in the LSM software.
  6. Initial programming of the locking device to be networked has been successfully completed.
  7. RouterNode2 can be reached via the network and you know its IP address.
  8. The programmed locking device features an installed LockNode and you know its chip ID.
  1. Select "Network/WaveNet network" and press the "Launch" button to open WaveNet Manager.
  2. Enter the password.
  3. Right-click on "WaveNet_xx_x".
  4. Initialize the RouterNode2 first, e.g. using the option "Add: IP or USB router".
  5. Follow the dialogue instructions and incorporate the RouterNode2 into your WaveNet radio network using its IP address.
  6. Initialize the locking device's LockNode by right-clicking on the newly added RouterNode2 and select the "Search by chip ID" option.
  7. Follow the dialogue instructions and use the associated chip ID to assign the locking device or its LockNode to the RouterNode2.
  8. Click on the "Save", "Exit" and "Yes" buttons one after another to close WaveNet Manager.
  9. Import the new settings and assign them to the corresponding communication node.