Possible tasks - LSM 3.5 SP3 Business + Prof.
The following tasks are available in the drop-down menu:

Task | Description |
|---|---|
Set output | A digital output (e.g. on SmartRelay 3) becomes active. The level becomes 1 or 0, depending on the type of output. |
Reset output | A digital output (e.g. on SmartRelay 3) is no longer active. The level becomes 1 or 0, depending on the type of output. |
Read door monitoring | Reads a locking device’s DoorMonitoring events. |
Configure door monitoring | Changes the DoorMonitoring settings. Use the Options button to specify the required settings:
|
Remote unlocking | Performs a remote opening (locking device engages for the configured duration). |
Activate input event | Activates input events in the selected external LockNodes or in locking devices with integrated LockNodes. These are then visible in the database and for the RouterNode. Input events are different here, depending on the type of LockNode:
|
Deactivate input event | Deactivates input events in the selected external LockNodes or in locking devices with integrated LockNodes. These are then no longer visible in the database and for the RouterNode. Input events are different here, depending on the type of LockNode:
|
Test Lock Node | Pings a LockNode to verify whether it can be reached. |
Program locks | Performs an emergency release (locking device remains engaged until you perform a remote opening). |
Activate lock | Re-activates deactivated locking devices. |
Deactivate lock | Deactivates the locking device (locking device remains disengaged until it is reactivated; exception: red master transponders can also engage deactivated locking devices). |
Program locks | Programs the locking device (complete reprogramming). |
Read lock state | Reads the locking device status (e.g. battery level). |
Set clock | Reprograms only the time (faster than complete reprogramming and less power consumed). |
Read Audit Trail | Reads the access list in the locking device. |