Resetting the programmed LockNode and programmed locking device - Step-by-Step WO
Resetting the LockNode
- SmartIntego-Tool (WO) opened.
- Second locking device of the same type available.
- GatewayNode available.
- SI.SmartCD available.
- Create a second project with a different SID in the SmartIntego tool (WO) (see Createing a SmartIntego project).
- Add the GatewayNode to this project (see Add GatewayNode).
- Add the second locking device (see Add LockNodes).
- Program the LockNode of the second locking device and the second locking device (see Programme locking device).
- Second system set up.
- Remove the LockNode from the old locking device (see quick guide or manual).
- Remove the LockNode from the second locking device (see quick guide or manual).
- Install the LockNode of the old locking device in the second locking device.
- The locking device beeps and flashes red four times.
- Remove the LockNode of the old locking device from the second locking device.
- Reinstall the LockNode of the old locking device into the old locking device.
- The locking device beeps and flashes red four times.
- LockNode is reset.
- Then reset the second locking device, LockNode and GatewayNode with SmartIntego Manager and the SmartIntego tool (WO) if necessary.
Re-set locking device
- SmartIntego-Tool (WO) opened.
- LockNode reset as described.
- Position the programming device on the locking device (example: locking cylinder).

- Read the locking device using Tools and .

- Summary of the read locking device is displayed.

- Click on the Reset button
- Locking system password is queried.

- Enter the locking system password.
- Click on the button OK.
- The locking device is reset.
- Locking device and LockNode reset.