Connecting SmartIntego to the integrator system - Step-by-Step WO
All SmartIntego components set up are configured with individual data in the system.
This data must be communicated to the integrator system after each change to the SmartIntego components. The most important data for the integrator system and communication are:
- Device address (all components)
- Device address for locking devices with two card readers
- IP address (TCP GatewayNodes)
- Segment address (RS-485-GatewayNode)
- Locking device connection to the GatewayNode
- Unique hardware number
- Locking devices: PHI
- GatewayNodes and LockNodes: Chip ID
You can also transfer additional information to the integrator system:
- Configuration
- Locking device status
- Quality of connection (based on last data packet)
- ...
Please refer to the integrator system documentation for the required information.
NOTE
CSV export for integrator systems after update
After an update from version 2.1 to version 3.0, the SmartIntego Manager must be started once before you export CSV files.
You can export all information together as a CSV file:
Integration into the integrator system can be different (import or manual transfer). In any case, you must prevent deviations from the actual configuration. This could have different effects:
- Opening of wrong doors
- Incorrect authorisations
- Double doors (double configuration in integrator system)
- Doors that no longer open
- ...