- All GatewayNodes powered and mounted.
- TCP configuration completed (seeConfiguring GatewayNodes (TCP)).
Unreachable IP addresses are skipped. - Start IP address of the range must be physically reachable.
- SmartIntego Manager opened.
- Right-click on the navigation root (WaveNet_XX_X).
- The window Administration opens.

- Select the option
Add IP or USB gateway.
- Click on the button OK.
- Window Administration closes.
- The window Add IP or USB Gateway opens.

- Specify the start IP address of the IP range and the last digit of the end IP (example: Start-IP: 192.168.100.100, End IP: 192,168,100,110).
- Click on the button OK.
- Window Add IP or USB Gateway closes.
- Right-click the entry of the new GatewayNode.
NOTE
Name assignment by name list
If you are using a name list (Creating, expanding and importing a name list see), you no longer need to name the GatewayNodes.
- The window Administration opens.
- Select the option
Set name.
- Click on the button OK.
- Window Administration closes.
- The window for naming opens.
- Specify the name of your GatewayNode.
- Click on the button Save.
- Name assignment window closes.
- SmartIntego Manager contacts the GatewayNode.
- SmartIntego Manager assigns GatewayNode device address.
- SmartIntego Manager saves routing table in the GatewayNode.
- If necessary, repeat the designation for the other GatewayNodes.
NOTE
Data loss due to improper termination
The data is not transferred to the SmartIntego tool (WO) until the SmartIntego Manager is properly ended. After saving, the files are permanently saved in the * ikp file in the SmartIntego tool (WO).
- Click on the Save button.
- Close SmartIntego Manager correctly using the button Exit.