Signalling the operating status - WaveNet

RouterNodes

Device

Signalling

Meaning

reaction

WNM.RN2.ER.IO

Flashing, ~1.5 Hz (green LED on cover)

WaveNet configuration available, RouterNode is ready for operation.

Flashing, ~0.3 Hz (green LED on cover)

no WaveNet configuration present.

  1. Add the RouterNode to your WaveNet (see Add RouterNode to WaveNet).

Flashing, briefly (red LED on cover)

Power-on reset.

Flickering (green LED on cover)

Data transfer.

Continuous lights (red LED on cover)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WNM.RN.R.IO

WNM.RN.CC.IO

WNM.RN.CR.IO

WNM.RN.EC.IO

Flashing, ~1.5 Hz (green LED)

Ready to receive.

Flashing (green LED)

Data transfer.

Permanent light (red LED)

  • Software problem
  • Problem with the power supply
  • Hardware problem
  1. Perform a power-on reset (see RouterNodes).
  2. Check the power supply.
  3. Replace the device (see Reprogram or replace the device).

LockNodes

Device

Signalling

Meaning

reaction

WNM.LN.I

WNM.LN.I.MP

4x beeping (after contacting)

LockNode and locking device connected.

No signal (after contacting)

LockNode and locking device not connected.

  1. Check the batteries (see leaflet on locking cylinders).
  2. Reset the LockNode (see LockNodes).

WNM.LN.I.S2

4x beeping (after contacting)

LockNode and locking device connected.

No signal (after contacting)

LockNode and locking device not connected.

  1. Check the batteries (see SmartHandle AX manual).
  2. Reset the LockNode (see LockNodes).

WNM.LN.I.SH

4x beeping (after contacting)

LockNode and locking device connected.

No signal (after contacting)

LockNode and locking device not connected.

  1. Check the batteries (see SmartHandle manual).
  2. Reset the LockNode (see LockNodes).

WNM.LN.I.SREL2.G2

WNM.LN.I.SREL.G2

4x flashing (after contacting)

LockNode and SmartRelay connected.

No signal (after contacting)

LockNode and SmartRelay not connected.

  1. Check the power supply of the SmartRelay.

CompactReader LockNode (not retrofittable)

3x flashing, followed by 4x flashing (after battery change)

Power-On-Reset CompactReader, LockNode and CompactReader connected.

3x flashing (after battery change)

Power-On-Reset CompactReader, LockNode and CompactReader not connected.

LockNode and CompactReader are permanently connected.

  1. Reset the CompactReader.
  2. Replace the device (see Reprogram or replace the device).

4x flashing (after configuration)

LockNode configured in the CompactReader.

No signal (after configuration)

LockNode not configured in the CompactReader.

  1. Check the batteries (see CompactReader Quick Reference Guide).
  2. Reset the CompactReader.
  3. Replace the device (see Reprogram or replace the device).

WNM.LN.R

Flickering (signal LED)

no WaveNet configuration present.

  1. Add the RouterNode to your WaveNet (see Add RouterNode to WaveNet).

1x (signal LED)

Transmission/reception power between LockNode and WN.XN.XR poor (check by pressing the button marked Init)

Improve the signal quality (see Improving signal quality).

2x (signal LED)

Transmission/reception power between LockNode and WN.XN.XR sufficient (check by pressing the button marked Init)

3x (signal LED)

Transmission/reception power between LockNode and WN.XN.XR optimum (check by pressing the button marked Init)

WNM.LN.C

2X short (red LED)

Power-on reset.

Flickering (alternating red and green)

Data transfer from/to LockNode.

Discontinued products

Device

Signalling

Meaning

reaction

WN.RN.XX

2X short (red LED)

Power-on reset.

1x (signal LED)

Transmit/receive power between two WN.RN.R poor (test by pressing button on baseboard).

Improve the signal quality (see Improving signal quality).

2x (signal LED)

Transmit/receive power between two WN.RN.R sufficient (test by pushing button on baseboard).

3x (signal LED)

Transmit/receive power between two WN.RN.R optimum (test by pressing button on baseboard).

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.LN.C

2X short (red LED)

Power-on reset.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RN.R

Slow flashing (green LED)

Ready to receive.

Fast flashing (green LED)

Data transfer from/to LockNode.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RN.XC (Master)

WN.RN.CN.XC (Master)

Flickering (red LED) and green LED off.

No slave found in segment.

  1. Check the cable connection to the slave.
  2. Check the functionality of the slave.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RN.CX (Slave)

WN.LN.C (Slave)

Flickering (red LED) and green LED off.

No master found in segment.

  1. Check the cable connection to the master.
  2. Check the functionality of the master.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.LN.R

2X short (red LED)

Power-on reset.

1x (signal LED)

Transmit/receive power between LockNode and WN.XN.XR poor (check by pressing a button on the LockNode baseboard).

Improve the signal quality (see Improving signal quality).

2x (signal LED)

Transmit/receive power between LockNode and WN.XN.XR sufficient (test by pressing a button on the LockNode baseboard).

3x (signal LED)

Transmit/receive power between LockNode and WN.XN.XR optimal (check by pressing a button on the LockNode baseboard).

1x short (red LED)

Battery full (check after power-on-reset).

1x long (red LED)

Battery low (check after power-on reset).

  1. Replace the batteries (see Battery change for external LockNodes).

1X long, four seconds (red LED)

Battery very weak (check after power-on reset).

  1. Replace the batteries (see Battery change for external LockNodes).

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RN.CC

1x long (yellow LED)

Power-on reset.

Light (green LED)

Upstream data transmission (slave sends to master).

Lights (dark green LED)

Downstream data transmission (master sends to slave).

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.CN.UX

1x long (yellow LED)

USB correctly detected and power-on reset.

Flashing, slow (green LED)

Ready to receive

Flashing, fast (green LED)

Data transfer from/to LockNode.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RP.CC

Permanent lights (yellow LED)

Power supply available.

Light (green LED)

Upstream_Data transmission.

Lights (dark green LED)

Downstream data transmission.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).

WN.RN2

Flashing (alternating red and green)

Reset is performed (firmware dependent).

Flashing, 1.5 (green)

no WaveNet configuration present.

  1. Add the RouterNode to your WaveNet (see Add RouterNode to WaveNet).

Flashing, 1 s

WaveNet configuration available, RouterNode is ready for operation.

Flashing, 0.5 s

Data transfer.

Permanent light (red LED)

Software or hardware defect.

  1. Perform a power-on reset (see RouterNodes).
  2. Replace the device (see Reprogram or replace the device).