Extended configuration with SmartOutput modules - SmartRelay 3 system

Unlocking in the authorised period (close relay contacts)

Automatic unlocking

Manual unlocking

always

only if locked

always

only if locked

Not possible

  • Controller: Closes relay contacts (unlocked) as soon as authorisation begins in the time zone plan. Not affected by identification media during the authorised period.
  • SmartOutput module: Closes relay contacts (unlocked) as soon as authorisation begins in the time zone plan. Not affected by identification media during the authorised period.

Not possible

  • Controller: Closes relay contacts (unlocked) as soon as identification medium is actuated after the start of the authorisation in the period. Thereafter, no influence by identification media in the remaining authorised period.
  • SmartOutput module: Closes relay contacts (unlocked) as soon as authorisation begins in the time zone plan and identification medium is reserved. No affected by identification media during the remaining authorised period.

Locks in unauthorised period (relay contacts open)

Automatic locking

Manual locking

always

only if locked

Not possible

Not possible

  • Controller: Opens relay contacts (locked) as soon as authorisation ends in the time zone plan. Identification media closes relay contacts for set pulse duration during the remaining unauthorised period.
  • SmartOutput module: Opens relay contacts (locked) as soon as authorisation ends in the time zone plan. Identification media closes relay contacts for set pulse duration during the remaining unauthorised period.