Flip-flop - SmartRelay 3 system
The switching time for the relay in the controller can be freely programmed between 0 s and 25 s. If the controller relay needs to be permanently operated, you can activate flip-flop mode.
IMPORTANT
Changing over the relay contact if power fails
The relays in the controller are not bi-stable. Consequently, permanent power is required for switched mode. Relays are no longer supplied with electricity if there is a power outage. In such cases, they switch to a power-off state even without using an identification medium, depending on the original position.
- Connect external components in such a way that a power-off state poses no risks.
NOTE
The flip-flop option is not available if the SREL3 ADV system is used with SmartOutput modules.
- LSM 3.4 SP1 or higher installed.
- Components connected to power.
- Components wired correctly (see wiring).
- Controller has already been programmed.
- Double-click on the SmartRelay 3 entry in the matrix to open the settings.
- Change to the Configuration/Data tab.
- Enable the
Flip Flop checkbox.
- Click on the Apply button.
- Click on the Exit button.
- Execute programming (see Programming).
- Flip-flop mode is activated.