Initial programming via TCP/IP - SmartRelay 3 system

In some use cases, the controller needs to be installed first and then programme the address (pre-installed reader). It may no longer be possible to reach the controller with a USB cable after installation. Whatever happens, an IP address assigned to the controller and known to LSM requires initial programming via TCP/IP.

This problem can be avoided if the controller is first programmed via a USB cable separately from other components. During programming, a valid IP address is issued and saved to the controller. The controller is then reset but the IP address is retained.

Initial programming with USB cable and address assignment

Carry out initial programming as described in Configuration.

NOTE

notice

In this case, external components do not need to be connected.

Resetting the controller

Reset the controller as described in Resetting controller with a USB cable.

Installing the controller

Install the controller in its final place of use. Connect the controller to the other components and the power supply (see wiring).

Programming via TCP/IP

Execute programming via the previously assigned TCP/IP address (see Programming).

The SREL3 ADV system is now ready for use.