Reader - SmartRelay 3 system

Reader connection

SREL3 controller connection

Signal

A

A1/A2/A3

RS-485: Data line A

B

B1/B2/B3

RS-485: Data line B

-

-

GND. Used to establish the common ground reference potential for the data lines. Any ground connection to the SREL3 controller.

+

+

VIN. Connection for power supply (external or via controller).

-

- (optional)

GND. Connection for external power supply. Electrically connected to reader port 3. Only required with external power supply.

WP version

The weatherproof WP version of the reader is supplied with a 2 m long, pre-assembled cable.

Reader connection

Wire colour in cable

SREL3 controller connection

Signal

A

yellow

A1/A2/A3

RS-485: Data line A

B

brown

B1/B2/B3

RS-485: Data line B

-

green

-

GND. Used to establish the common ground reference potential for the data lines. Any ground connection to the SREL3 controller.

black (brought out only on the reader's end)

-

GND. Connection of the cable shielding to the common ground reference potential of reader and controller.

+

white

+

VIN. Connection for power supply (external or via controller).

-

- (optional)

GND. Connection for external power supply. Electrically connected to reader port 3. Only required with external power supply.