SmartHandle MP battery warning - SmartHandle 3062
- Warning Level 1:
- Low batteries: 8 short audible signals + LED flashes red briefly 8 times before engaging. Batteries will soon be empty. Replace batteries in the SmartHandle.
- Warning Level 2:
- Extremely low batteries: 8 short audible signals 30 seconds long + LED flashes red twice briefly with one second pause between each one during 30 seconds Emergency battery warning: batteries are almost completely empty. Replace the batteries in SmartHandle immediately.
- Once Warning Level 2 has been emitted for the first time, the cylinder can be opened a maximum of 50 more times.
- After reaching this number of opening operations or after about 4 weeks, SmartHandle automatically switches to freeze mode. Once at this warning level, SmartHandle can now only be activated using a SimonsVoss programming device or using a G2 battery replacement card. The battery replacement card re-activates the SmartHandle for about 30 seconds. During this time the SmartHandle can be operated as usual with a suitable identification medium to open the door for a battery change.