Step 2: Bolt sensor installation - SmartHandle 3062

Preparing the bolt sensor

The bolt sensor (C) must be attached to the installation tool (D) as shown in the following image in preparation for installation:

 

The bolt sensor cone may need to be moved, depending on the door lock used. In most cases, the cone can remain in the pre-set "Position 1".

Follow the steps below to move the cone:

 

  1. Ensure that the bolt sensor (C) is placed firmly on the installation tool (D).
  2. Simply release the outer ring segment from point X (see image above) by turning in the direction of the arrow.
  3. Move the cone parallel to the axial direction to release it.
  4. Pull the cone into the required position.
  5. You will find the correct position online at www.simons-voss.com.
  6. Each bar corresponds to a position. The first bar corresponds to the non-approved zero position. The image shows the cone at Position 1.
  7. Turn the ring segment back to its original position until you hear it snap back into position.

Determining the direction of installation

  • The door lock must be in the unbolted position when it is installed.
  • The square opening in the bolt sensor must always point to the right towards the door hinges when the bolt sensor is fitted. This determines whether the bolt sensor needs to be fitted from the inner or outer side of the door.

Fitting the bolt sensor from the inner side

  1. Carefully release cable from the bolt sensor (C) cable duct to guide the plug out onto the inner side.
  2. Push the bolt sensor into the profile cylinder opening via the installation tool (D) until it stops.
  3. The square opening in the bolt sensor must always point to the right towards the door hinges.
  4. Rotate bolt sensor 90º, so that the bolt sensor opening points downwards.
  5. Pull the installation tool to remove.
  6. The bolt sensor remains in the lock. The rectangular opening in the bolt sensor faces downwards.

Fitting the bolt sensor from the outer side

  1. Push the bolt sensor (C) into the profile cylinder opening via the installation tool (D) until it stops.
  2. The square opening in the bolt sensor must always point to the right towards the door hinges.
  3. Rotate bolt sensor 90º, so that the bolt sensor opening points downwards.
  4. Pull the installation tool to remove.
  5. The bolt sensor remains in the lock. The rectangular opening in the bolt sensor faces downwards.