SmartHandle G1 - SmartHandle 3062

LSM version 3.0 or higher and a Smart CD G2 programming device or newer are required for its use.

Please select 'Locking Cylinder G1' as the locking type in the case of SmartHandle G1. SmartHandle is detected and incorporated into the locking plan during programming and then displayed in the lock configuration. All the same functions as in TN4 cylinders (G1) are available.

  • Open the management and programming software (LSM) and select in the database.
  • Select locking system (if several are available)
  • Select 'New lock'
  • Select 'Locking Cylinder G1' as lock type
  • Give the lock a name
  • You can select "Section" as an option
  • Confirm by pressing 'Accept.'
  • Highlight the lock (so that it appears in BLUE)
  • Place the SmartHandle at a distance of about 10 cm from the programming device, fitting the cover on the electronics side if possible.
  • Select 'Programming --> Locking device'
  • Click 'Programme'
  • Wait until the programming process is complete