Disassembling DoorMonitoring components - SmartHandle 3062
The SmartHandle must be fully detached first before the bolt sensor and fastening screw sensor can be dismounted.
Dismount bolt sensor
- Disconnect all cables from one another.
- Conventional fastening system: Carefully press the snap-in adapter together and pull out through the profile cylinder opening.
- Rotate bolt sensor 90º to the left, so that the button faces downwards.
- Pull the bolt sensor out from the profile cylinder in the mortise lock horizontally.
Dismount fastening screw sensor
- Disconnect all cables from one another.
- Grip the fastening screw head slit with a small screw driver.
- Carefully prise out the fastening screw head.
- Pull out the fastening screw head against the spring force.