Disassembling DoorMonitoring components - SmartHandle 3062

The SmartHandle must be fully detached first before the bolt sensor and fastening screw sensor can be dismounted.

Dismount bolt sensor

  1. Disconnect all cables from one another.
  2. Conventional fastening system: Carefully press the snap-in adapter together and pull out through the profile cylinder opening.
  3. Rotate bolt sensor 90º to the left, so that the button faces downwards.
  4. Pull the bolt sensor out from the profile cylinder in the mortise lock horizontally.

 

Dismount fastening screw sensor

  1. Disconnect all cables from one another.
  2. Grip the fastening screw head slit with a small screw driver.
  3. Carefully prise out the fastening screw head.
  4. Pull out the fastening screw head against the spring force.