Overview of protocol generations - LSM 3.5 SP3 Basic Online
|
G1 |
G2 | |
|---|---|---|
|
Access rights administration: |
Locking devices |
Locking device and ID medium (only ID medium in VN) |
|
Number of locking devices: |
16,000 |
64,000 |
|
Number of transponders: |
8,000 |
64,000 |
|
Number of locking systems on a transponder: |
3 |
4 x G2 + 3 x G1 |
|
Time zone groups: |
5+1 |
100+1 |
|
Loggable access events in a locking device: |
Cylinder: 1,000 |
Cylinder: 3,000; SmartRelay: 3,600 (200 as Gateway) |
|
Physical access list on transponder: |
No |
1,000 per G2 locking plan (including date, time, locking device ID) |
|
Procedure for group administration: |
Adjustable; number is defined in the group |
No pre-setting required; rights and exceptions are entered onto transponder |
|
Replacement transponders: |
7 replacement transponders using overlay mode |
No pre-setting required |
|
Network-capable: |
Yes |
Yes |
|
Virtual network: |
No |
Yes, circulate Block IDs in VN |
|
Engage interval: |
5 or 10 sec. |
1 to 25 sec.; engage time can be doubled on an individual basis for transponders – max. 25 sec. |
|
Time-restricted authorisation: |
Yes |
Yes |
|
Battery warning: |
Level 1; Level 2; storage mode |
Level 1; Level 2; freeze mode |
|
Battery replacement: |
SmartCD |
Battery replacement transponder together with authorised transponder or SmartCD |
|
LSM/LDB: |
All versions |
LSM 3.0 and higher |
|
Active/passive: |
Yes / yes |
Yes / yes |