Programming distance - LSM 3.5 SP3 Basic Online

A specific distance must be kept between the programming device and the components for successful programming and read processes.

SmartStick AX

After waking up the lock, the SmartStick AX has a range of up to 300 cm.

SMARTCD.G2

  • The distance between SMARTCD.G2 and active components, such as locking cylinders or transponders, should be about 20 cm.
  • Ensure that no other active components are in the immediate surrounding area during the programming or read process (radius of about 1.5 m to the SMARTCD.G2).

NOTE

notice

The programming distance between SMARTCD.G2 and SmartRelay or biometric reader must be exactly 40 cm!

SMARTCD.MP

  • The thumb-turn on the electronics side of the locking cylinder (black ring between the thumb-turn and the profile cylinder housing) must be held directly against the antenna symbol on the SMARTCD.MP.
  • Hold the locking cylinder against the antenna symbol for the whole process.
  • You can also use the SMARTCD.MP to programme cards by holding them directly on the programming device.

SMARTCD.HF

  • Position the card or the tag, so that it is flush with the lower, left-hand corner of the SMARTCD.HF.