BKS - Digital SmartHandle AX

Remove fittings

  1. Remove the panic bar as described in the manufacturer's documentation except for the adapter plate.
  2. NOTE

    notice

    Third party product with own documentation

    The panic bar holder is a third-party product.

    1. Please follow the manufacturer's instructions and safety instructions.
  3. Remove the covers of the escutcheons with a slotted screwdriver.
  4. Unscrew the screws of the escutcheon bases.
  5. Unscrew the screws of the mounting plate.
  6. Pull out the fitting with the adapter plate and the square.
  7. SmartHandle AX is removed from the door.
  8. Unscrew the screws that fix the SmartHandle AX to the adapter plate.
  9. Adapter plate is removed.
  10. Push the locking pin of the square inward and pull the square out of the assembly.
  11. The square is removed.

Removing the handle from the assembly

  1. Insert the Allen wrench into the hole provided in the square socket.
  2. Push the Allen wrench towards the nearer edge and hold it pressed.
  3. Remove the handle from the assembly.
  1. SmartHandle AX is disassembled.