Installing the fitting for CISA - Digital SmartHandle AX
- Door pre-drilled.
- PH2 screwdriver at hand.
- TX15 screwdriver at hand.
- Vernier calliper at hand.
- Saw at hand.
- Measure the door thickness.

- Mark the sawing points on the screws and spindle.
- Use a suitable saw to cut the screws and spindle.

- Insert the sleeve nuts into the adapter plate.

- Place the adapter plate on the electronic fitting.

- Align the holes in the adapter plate with the threads in the fitting.
- Fasten the adapter plate firmly in a criss-cross sequence (PH2, torque 1.1 Nm).


- Insert the spindle with the pin side into the fitting.

- Insert the fitting with the adapter plate and spindle into the door.

- Screw the fitting firmly into place in the centre (PH2, torque 1.1 Nm).

- Screw the adapter plate firmly into place below the keyhole (PH2, torque 1.1 Nm).

- Fasten the wood screw as described in the CISA documentation.

- Insert the dummy cylinder.
NOTE
Feed the blank cylinder into the hole using a screwdriver
It is difficult to position the blank cylinder correctly, especially in thick doors.
- Insert a screwdriver into the hole in the blank cylinder.
- Position the blank cylinder using the screwdriver.


- Push the handle onto the outer fitting.

- Firmly fasten the grub screw on the outside handle (TX15; torque: 5.0 Nm).

- Screw the dummy cylinder firmly into place (PH2, torque 1.1 Nm).

- Fitting is now installed.