Programming - Digital SmartHandle AX

The configuration is described in the LSM, but is also included in the AXM in a similar form.

  1. Current version of LSM/AXM installed.
  2. NOTE

    notice

    Compatibility between driver and firmware

    To use MIFARE DESFire ident media with a SmartHandle AX with firmware version 1.1.604 or higher, the SV driver 7.27 (from LSM 3.5) or higher is required.

  3. LSM open.
  4. SmartStick AX, SmartCD.MP or SmartCD2.G2 connected (recommendation: SmartStick AX).
  1. Select the locking system that you require. Use the ... button to open the locking system properties and use the and buttons to select the required lock system.
  2. Click on the button to add a new locking device.
  3. The New lock window will open.
  4. Open the Area drop-down menu.
  5. Select the area.
  6. Open the drop-down menu Lock type.
  7. Select the AX SmartHandle item.
  8. Complete the rest of the form.
  9. Click the button Save & next.
  10. Locking device has been added.
  11. Click on the Exit button.
  12. Window closes.
  13. Highlight the entry on the SmartHandle AX in the matrix.
  14. Tap SmartStick AX on or SmartHandle AX to align with SmartCD.MP SmartHandle AX or position SmartCD.G2 about ten centimetres from SmartHandle AX.
  15. NOTE

    notice

    Duration of initial programming

    A large amount of data is transferred during initial programming. The data transfer speed is significantly higher with a SmartStick AX or a SmartCD.MP (and the programming time is therefore shorter).

    1. If possible, use a SmartStick AX or a SmartCD.MP for initial programming.
  16. Right-click on the SmartHandle AX entry in the matrix to open the context menu.
  17. Select the Programming item.
  18. Open the drop-down menu Type.
  19. Select the entry Card reader (SmartCD MP) or SmartCD.
  20. Click on the Programming button.
  21. Programming launches.
  22. Wait for programming to complete.
  1. SmartHandle AX is programmed.

NOTE

notice

First transponder activation rejected after initial programming of AX products

If a transponder is the first identification medium to be activated after initial programming, the transponder can be rejected once and synchronised with the locking device in the background. Transponders will then function as normal.