Installing the fitting - SmartHandle AX Advanced
- Door pre-drilled.
- Blind rivet nut pliers at hand.
- PH2 screwdriver at hand.
- TX15 screwdriver at hand.
- Caliper gauge at hand.
- Saw at hand.
- Fit the blind rivet nuts into the pre-drilled holes.


- For non-MO: insert the blank cylinder.
NOTE
Feed the blank cylinder into the hole using a screwdriver
It is difficult to position the blank cylinder correctly, especially in thick doors.
- Insert a screwdriver into the hole in the blank cylinder.
- Position the blank cylinder using the screwdriver.


- For non-MO: screw the dummy cylinder firmly into place (PH2; torque: 1.1 Nm).

- Use the 12 mm screws to fix the outer fastening plate onto the outer side of the door (PH2) with the tip facing upwards (PH2; torque 3.0 Nm).
You can identify the outer fastening plate by its elongated holes. 

- Insert the module support into the fastening plate.

- Slide the module support upwards.

- Module support snaps into place.
- Use the 18 mm screws to fix the module support onto the fastening plate (PH2; torque: 3.0 Nm).

- Place a cover on the fastening plate at the top.

- Fold down the cover.

- Push the cover against the door, sliding it upwards at the same time.

- Cover snaps into place.
- Press the inlay into place.

- Fit the outside handle.

- Firmly fasten the grub screw into the outside handle (TX15; torque: 5.0 Nm).

- Measure the door thickness.

- Mark the sawing point on the spindle.
- Trim the spindle with a suitable saw.

- For 8.5 mm, 9 mm and 10 mm spindle: slide the adapter sleeve into the centre of the spindle. Use a punch and hammer to make an indent in the adapter sleeve to prevent it from slipping.


- Insert the spindle into the door as far as it will go.

- Use the 12 mm screws to mount the inner fastening plate onto the inner side of the door with the tip facing upwards (PH2, Drehmoment 3,0 Nm).


- Use the 18 mm screws to fix the module support onto the fastening plate (PH2; torque: 3.0 Nm).

- Place a cover on the fastening plate at the top.

- Fold down the cover.

- Push the cover against the door, sliding it upwards at the same time.

- Cover snaps into place.
- Press the inlay into place.

- Attach an inside handle.

- Fasten the grub screw on the inner handle firmly (TX15; torque: 5.0 Nm).

- SmartHandle AX Advanced fully installed.