Create fire service transponders - LSM 3.5 SP3 Basic
- You have already created at least one locking system.
- Create a new "red" common locking level, using Edit/New locking system, for example.
- Add a new area, such as "All locking devices", and use "Door administration" to assign all the locking devices required to this area.
- Add a new "Fire service" transponder group to the common locking level.
- Click on the "Authorisations" button in the properties for the "Fire service" transponder group.
- Enable the "All systems" checkbox to authorise this transponder group for all locking devices in general.
- Click on the "OK" button to save the settings.
- Add a new transponder – "Fire service transponder 1", for example – to the transponder group and programme it. All locking devices also need to be reprogrammed. Note the new programming requirement which has now appeared.
The "Fire service transponder 1" fire service transponder created in this step is authorised for all locking devices. Even deactivated locking devices can be opened in the red level, making it markedly different from "green" and "blue" levels.