Installation with clip-on cover plate - Digital Cylinder AX (Z5)

  1. Special tool available.
  2. 1.5 mm hexagonal wrench available.
  3. PH2 screwdriver at hand.
  1. Align the thumb turn horizontally.
  2. Attach the special tool.
  3. Align the special tool so that the logo is parallel to the recess.
  4. Hold the special tool and thumb turn cap firmly at the same time and turn them together 1-2° clockwise first and then counter-clockwise.
  5. NOTE

    notice

    Slipping when turning

    The surface of the thumb turn cap can be slippery and the cap can be difficult to turn (especially with WP versions, recognizable by the blue cylinder neck ring or the lasered marking on the inner side of the cylinder profile).

    1. Wear non-slip gloves.
  6. Remove the tool and cover.
  7. NOTE

    notice

    Use the supplied hexagonal wrench.

    The special tool is supplied with a hexagonal wrench.

    1. Use this hexagonal wrench to mount and dismount the electronic thumb turn.
  8. Insert the hexagonal wrench into the hole provided until it stops.
  9. Turn the hex wrench 270 degrees counterclockwise.
  10. Pull out the hexagon wrench again.
  11. Pull off the thumb turn.
  12. Electronic thumb-turn is disassembled.
  13. Insert the Digital Cylinder AX into the mortise lock.
  14. Screw the Digital Cylinder AX tight with the face plate screw.
  15. Mount the cover plates if necessary.
  16. Align the thumb-turn mount horizontally.
  17. Attach the thumb turn.
  18. NOTE

    notice

    Use the supplied hexagonal wrench.

    The special tool is supplied with a hexagonal wrench.

    1. Use this hexagonal wrench to mount and dismount the electronic thumb turn.
  19. Insert the hexagonal wrench into the hole provided until it stops.
  20. Turn the hex wrench 270 degrees counterclockwise.
  21. Pull out the hexagon wrench again.
  22. Put on the cover.
  23. Turn the cover clockwise.
  24. The cover snaps into place with one click.
  25. The electronic thumb-turn is installed.
  26. Carry out a functional test (see Functional test).
  27. You must also carry out the anti-panic function test on anti-panic cylinders (see AP functional test).
  1. Digital Cylinder AX is installed with clip-on cover plate.