Installing the lever cylinder - Digital Cylinder AX (Z5)

  1. Open-ended/ring spanner SW22 available.
  2. Open-ended/ring spanner SW10 available.
  1. Insert the Digital Lever Cylinder AX into the opening provided in the locker door.
  2. Place the large round washer on the cylinder profile so that it is flush with the inner side of the locker door.
  3. Place the nut on the cylinder profile and fasten it into place (SW22).
  4. Place the small washer on the end of the cylinder profile.
  5. Place the spindle bushing on the small washer.
  6. Place the lever on the spindle bushing.
  7. Place the second small washer on the lever.
  8. Then fasten the hexagon nut onto the lever (SW10).
  1. Digital Lever Cylinder AX is fully installed.