Technical specifications - VdS shunt lock
VdS approval numbers
- Activation unit - G101160 - Class C
- Deactivation unit - G101161 - Class C
- Block lock function - G102014 - Class C
Dimensional drawing
Drilling template: Activation and deactivation units
You can print out the drawing and use it as a drilling template.
NOTE
Ensure that the print settings are not set to reduce or enlarge. Use the lines under the drawings to check scale is correct.
Housing | Dimensions | 84.5 mm × 84.5 mm × 26 mm |
Colour | White | |
Material | S-B or ABS | |
Ambient conditions | Temperature range | -10 °C to +55 °C |
Standard protection rating | VdS environmental class II | |
Power supply | Operating voltage | 8 VDC to 16 VDC |
Power consumption per unit | max. 30 mA | |
Connections | Relay for switching output | Continuous current < 1 A |
Inrush current < 1 A | ||
Switching voltage < 40 VAC | ||
Switching capacity < 30 W / 60 VA | ||
Cover contact (normally open contact) | ≤ 100 mA | |
< 30 VDC | ||
Range of the transponder | With external antenna | 1 cm to 3 cm |
Radio emissions
23.5 kHz - 26.5 kHz | ≤ 18 dbµA / m (10 m distance) |
External antennas