Install reliable wiring - VdS shunt lock
- Always use shielded, twisted cables (e.g. standard telecommunication cable YST-Y).
- Reduce the clamping points to a minimum.
- Use appropriate terminals for shared junction boxes.
- Accidental contact between current-carrying wires and signal-carrying wires is prevented.
- Always connect a terminal to open wires to prevent short circuits.
- Accidental short circuits are prevented.
- Preferably use terminals to connect wires.
- Clamps are more reliable than twisting.
- Only remove the jacket and insulation from cables as far as necessary.
- Fold back unused wires and insulate them with heat-shrink tubing or elastic insulation tape.
- Connect the shielding to the earth solder terminals. Then connect the shield to a suitable earth potential on one side, e.g. a busbar or a ring earth electrode.
- Label the cables.
- This will make maintenance easier at a later stage.