Deactivation unit without activation unit - VdS shunt lock
If the alarm system continues to be operated using a conventional key, no activation units are required. A relay contact is required on the burglar alarm system, which is closed when the alarm system is activated.
- Connect the power supply to the deactivation unit.
- Connect pins 13 and a ground connection (e.g. pin 15) to the relay contact of the alarm system (potential-free closing contact).
- Connect any existing bolt switch contact to pins 12 and 15 (see also Optional bolt contact evaluation (global activation suppression)).
- If the alarm system is activated, pin 13 is pulled to ground. The reaction is the same as a deactivation request from an activation unit: The deactivation unit deactivates its locking device.
- It is no longer possible to operate the locking device when the alarm is activated.