Testing the block lock function - VdS shunt lock

  1. Press an authorised transponder on an activation unit twice in quick succession (0.5 s to 2 s).
  2. LEDs on deactivation units go out.
  3. Acoustic acknowledgement of the activation request sounds:
    Acknowledgement by activation master (jumper B1 on b/c): 2.5 s or
    acknowledgement by burglar alarm system (jumper B1 on a/b): Dependent on burglar alarm system
  4. Locking devices are deactivated.
  5. Alarm is activated.
  6. Check that the locking devices are deactivated.
  7. Press an authorised transponder on an activation unit twice again in quick succession (0.5 s to 2 s).
  8. Locking devices are activated.
  9. Activation unit signals that the locking devices have been activated:
    Acknowledgement by activation master (jumper B1 on b/c): Single short-long flashes or
    acknowledgement by burglar alarm system (jumper B1 on a/b): Double signal tone on activation unit
  10. LEDs of the deactivation units light up again.
  11. Alarm system is deactivated.
  12. Locking devices are activated and can be switched again.
  13. Check that the locking devices are activated.
  14. Repeat this function test several times.
  15. Set jumper B1 to a/b, if not already done (VdS-compliant acknowledgement by burglar alarm system).
  16. Close the housing with the cover.
  17. Stick the supplied VdS stickers onto the slotted screws.
  18. Components can no longer be tampered with undetected (sealing of the screws).
  1. Block lock function is set up.