Block lock components - VdS shunt lock
The block lock components are mounted in the protected area.
IMPORTANT
Electromagnetic interference
Digital components that are nearby can interfere with the activation units.
- Install the activation units at least 1.5 m away from other digital components.
- Unscrew the slotted screws.
- Remove the cover.
- Secure the component with two countersunk screws (ø 3.5 mm x 30 mm) and two dowels (S5).
The countersunk screws and the dowels are not included in the scope of delivery.