Testing the activation slave - VdS shunt lock

  1. Connect the activation slave to a power supply (for example a 9V block battery, see Connections of the activation slave).
  2. Connect the external antenna if you want to use it later (see Connections of the activation slave).
  3. Make sure that all components are correctly programmed (see Programming).
  4. Set jumper B1 to b/c (right).
  5. Press the transponder authorised on the activation slave twice briefly (0.5 s to 2 s) within range of the activation slave (with external antenna: 1 cm to 3 cm).
    The range of the antenna is restricted in VdS-compliant operation by the aluminium sleeve.
  6. Activation slave controls activation master.
  7. Activation slave receives deactivation acknowledgement and beeps for 2.5 s.
  8. Press the transponder authorised on the activation slave again twice briefly (0.5 s to 2 s) within range of the activation slave (with external antenna: 1 cm to 3 cm).
  9. Activation slave controls activation master.
  10. Activation master no longer receives a deactivation acknowledgement and beeps twice (short-long).
  11. Set jumper B1 to a/b (left).
  12. Connect the switching contact and pin 29 to the burglar alarm system (see Connections of the activation slave).
  13. Perform the activation test again. The acknowledgement of the activation comes from the burglar alarm system, but is output by the activation slave.
  14. Repeat the test several times.
  15. Then carry out the installation as described (see Installing the activation slave and Connections of the activation slave).