Function of the activation slave unit - VdS shunt lock
If an authorised transponder is activated on an activation slave, the activation slaves send an impulse (high-impedance mass-high-impedance) to the activation request line (pin 14).
The activation master receives this pulse and informs the burglar alarm system via the switch contact (see Switching contact) that the alarm system can be activated.