Connections of the activation master - VdS shunt lock

Connection

Meaning

PE

Connection for cable shield

1

Supply voltage (+V)

2

Supply voltage (ground)

3

Connection for external LED (+ anode, 5 VDC with built-in 100 Ω resistor)

4

Connection for external LED (- cathode with built-in 100 Ω resistor)

5

Potential-free changeover contact for switching the system (C=Common)

6

Potential-free changeover contact for switching the system (NC=Normally closed)

7

Potential-free changeover contact for switching the system (NO=Normally open)

8

Sabotage contacts

9

10

11

12

Activation request line from activation slaves (optional)

13

  • Deactivation acknowledgement line (input)
  • If pulled to ground, then no activation (Global activation suppression, see Global activation suppression (optional)).
  • Connection of a bolt contact evaluation (optional)

14

Deactivation request (output)

15

Ground (identical with connection 2)

16

Connection for external antenna (green)

17

Connection for external antenna (blue)

18

Connection for external antenna (ground/shield)

19

Connection for external antenna (red)

20

Connection for external antenna (yellow)

29

Acoustic activation acknowledgement by burglar alarm system (input)