Testing the activation master - VdS shunt lock
- Connect the activation master to a power supply (for example a 9V block battery, see Connections of the activation master).
- Connect the external separate antenna if you want to use it later (see Connections of the activation master).
- Make sure that all components are correctly programmed (see Programming).
- Set jumper B1 to b/c (right).
- Press the transponder authorised on the activation master twice briefly (0.5 s to 2 s) within range of the activation master (with external antenna: 1 cm to 3 cm).
The range of the antenna is restricted in VdS-compliant operation by the aluminium sleeve. - The relay switches and connects pins 5 and 7 (alarm system would now be activated).
- Activation master beeps for 2.5 s.
- Check whether the relay has switched.
- Press the transponder authorised on the activation master twice briefly again (0.5 s to 2 s) within range of the activation master (with external antenna: 1 cm to 3 cm).
- The relay switches and separates pins 5 and 7 (alarm system would now be deactivated).
- Activation master beeps twice (short-long).
- Set jumper B1 to a/b (left).
- Connect the switching contact and pin 29 to the burglar alarm system (see Connections of the activation master).
- Perform the activation test again. The acknowledgement of the activation comes from the burglar alarm system, but is output by the activation master.
- Repeat the test several times.
- Then carry out the installation as described (see Installing the activation master and Connections of the activation master).