Testing the deactivation unit - VdS shunt lock
- Connect the deactivation unit to a power supply (for example a 9V block battery, see Connections of deactivation unit).
- Position the deactivation unit next to the digital locking device (lock cylinder and SmartHandles max. 30 cm, SmartRelay 20 cm to 1 m).
- Make sure that all components are correctly programmed (see Programming).
- Connect pins 13 and 15 (temporarily).
- Lock is deactivated (beep at lock if necessary).
- LED on deactivation unit goes out.
- Lock no longer reacts to identification media.
- Disconnect pins 13 and 15 again.
- Locking device is activated (if necessary, signal tone on lock).
- LED on deactivation unit goes on.
- Lock reacts to identification media again.
- Repeat the test several times.
- Then carry out the installation as described (see Installing the deactivation unit and Connections of deactivation unit).