Controller - SmartRelay AX Classic

Housing

Dimensions

84.8 mm × 84.8 mm × 25.5 mm

Material

ABS

Colour

Signal white, similar to RAL 9003

Wiring to device

Flush-mounted

Power supply

  • VIN: 9 VDC - 32 VDC (power supply must be limited to 15 W)
  • Power consumption < 100 mA at 12 V
  • Reverse polarity protected

Backup battery

  • 1× CR1220 3 VDC
  • Approved manufacturers: Duracell, GP Batteries (Gold Peak), Murata, Panasonic
  • Batteries coated with bitter substances are not suitable.
  • Positive terminal upwards
  • Interchangeable
  • Duration >10 years (inactive), >2 years (active)
  • Status can be read out via LSM/AXM

Voltage output for reader

V OUT = VIN - 1 VDC

Auxiliary voltage output

  • V OUT = VIN - 1 VDC
  • Max. 50 mA

Ambient conditions

Operating temperature range

-20°C to +60°C

Temperature range (storage > 1 week, without battery)

-20°C to +50°C

Humidity

Max. extension 90% RH, non-condensing

Protection rating

IP40

Vibrations

Not approved for use when subject to permanent vibrations

Output relay

Output relay number

Output relay type

  • 1× NO
  • 1× NC

Output relay switching modes

Programmable.

  • Monoflop
  • Flip-flop

Output relay switching time

Programmable from 0 s to 25 s.

Output relay switching current

Max. 1 A (resistive load)

Output relay switching voltage

32 VDC (resistive load)/24 VAC

Digital outputs

Number of digital outputs

2x open drain

Digital outputs – switching voltage

Max. extension 32 VDC (resistive load)

Digital outputs – switching current

Max. 100 mA

Digital inputs

Number of digital inputs

Digital inputs – input voltage

Max. 32 VDC

Digital inputs – level

  • Low: 0 VDC to 0.5 VDC
  • High: 4 VDC to 32 VDC

Digital inputs – functions

  • Push-to-open (configurable)

External contact

For connecting external devices with relay contact

Switches auxiliary voltage output to a digital input

Interfaces

RS-485 interface

to readers of the SREL AX Classic

  • 1 port
  • Baud rate 1 MBd
  • Recommended length ≤ 150 m, absolute max. 300 m (depending on firmware and cable)
  • Recommended cable: CAT5 or better

☻wx

Serial interfaces

via digital outputs

  • Wiegand (without CLS card load signal)
  • OMRON (without CLS card load signal)

Feedback signals

Feedback signals

  • Internal: Visual (green LEDs inside the housing)
  • External: Optional (through digital outputs)

Programming

Programming

Programming requires a connected reader. Reader interfaces for programming:

  • Active (25 kHz)
  • RFID (13.56 MHz)
  • BLE
  • Optional: WaveNet (868 MHz)

See reader for details.

Loggable access events

Max. 3300

Real-time clock (RTC)

Deviation max. ± 20 ppm (≈ 10 minutes per year)