Information on cabling - SmartRelay AX Classic
Recommended cable types
Lines with data transfer | Cat 5 or installation cable for telecommunication systems (e.g. F-YAY 2x2x0.6) |
Cables with data transmission and power supply | Cat 5 or installation cable for telecommunication systems (e.g. F-YAY 2x2x0.6) |
Lines for power supply only | Any line (e.g. F-YAY 2x2x0.6) |
Further information on wiring
IMPORTANT
Malfunctions due to interference
Sources of interference may impair functional reliability.
- Observe the wiring instructions (see Wiring, block diagrams and application examples).
- Use shielded twisted-pair cables.
- Connect the cable shielding to the earth potential on one side.
NOTE
Operating voltage not reached
When selecting the power source, keep in mind that voltage drops may occur in live cables, potentially leading to a drop in operating voltage. Malfunctions may occur as a result. You can reduce a voltage drop using the following measures:
- Increase the operating voltage on the controller.
- Increase the connection cable cross-section.
- Equip the reader with its own power supply unit.