Controller - SmartRelay AX Classic
Abbreviation | Function |
|---|---|
Vin (9 - 32 VDC) | Power supply input (positive terminal) |
Earth (-) | Earth connection (negative terminal) |
Relay: NO | NO (normally open) relay contact, not connected to COM when in idle mode |
Relay: COM | COM (common) relay contact, connected to NO or NC depending on state |
Relay: NC | NC (normally closed) relay contact, connected to COM when in idle mode |
Reader: power supply + | Power supply output (positive terminal) for direct connection to the reader |
Reader: power supply earth | Earth connection (negative terminal) for direct connection to the reader |
Reader: data RS-485 B | RS-485 bus connection B to reader |
Reader: data RS-485 A | RS-485 bus connection A to reader |
Auxiliary voltage (≈ Vin - 1V) | Auxiliary voltage (positive terminal) for connecting external switches. The auxiliary voltage corresponds roughly to the input voltage minus the voltage drop (approximately 1 V). The dielectric strength of the external switches must be at least as high as the input voltage. |
Earth (-) | Earth connection (negative terminal) as common reference potential for the outputs |
Output 2 | Digital output (open drain) or Wiegand output (with pull-up resistor, without CLS) |
Output 1 | Digital output (open drain) or Wiegand output (with pull-up resistor, without CLS) |
Input 1 | Digital input, e.g. to switch the relay manually (e.g. with auxiliary voltage and button or 4-32 VDC for push-to-open) |
Input 2 | Reserved for future functions. |