Shorter LockNode response times (short wake-up period) - System description WO

For all actions on locking devices initiated remotely by the integrator system, the network-related delays accumulate (see also Communication between integrator system and locking devices). Such actions include, for example:

  • Remote opening
  • Openings with PIN code keypads
  • Programming the whitelist

Up to 12 seconds or more may elapse between the initiation of the action and a visible reaction.

This time can be shortened. The LockNodes in the locking devices save energy by only "waking up" periodically and checking whether they are currently being addressed. These intervals can be shortened.

The wake-up interval of the locking device is shortened in the integrator system (short wake-up period). The locking device then senses more quickly that it is activated and reacts more quickly.

  • This function can be activated or deactivated individually for each locking device (depending on the integrator).
  • This function can also be activated or deactivated in a time-controlled manner (depending on the integrator, e.g. only switched on during office hours).
  • The shorter wake-up interval increases power consumption. The standby battery life is reduced to 3.5 years with a permanently active shorter wake-up interval.

For details, please refer to the documentation of the integrator system.