Integrator whitelist - System description WO

The integrator whitelist is managed by the integrator himself and is the most important security mechanism in the SmartIntego locking system.

It acts as a fallback level if the integrator system is no longer reachable. Possible reasons for failure:

  • Power failure
  • Disruptions in the IT infrastructure
  • Faults in the integrator system
  • Hardware error

As soon as the locking devices no longer reach the integrator system, access authorisations can no longer be checked or received online. Authorised users would also no longer be able to open doors.

For this purpose, a whitelist is configured in the integrator system during the construction phase of a project and programmed into the locking devices.

Integrator whitelist properties:

  • Local check by closing after return timeout (no response from integrator system within five seconds)
  • No communication with integrator system
  • Default value: Five seconds
  • Prolonged card retention (approx. 5 seconds) also disengages permanently engaged locking devices
  • Additional functions such as office mode or long-term engagement not available
  • Whitelist authentication (offline) normally with the same card ID as online authentication. In special cases, a card can have an ID for online access and an ID for offline access.
  • Limited to 250 cards per lock (see integrator system documentation)
  • Individual, individual integrator whitelist for each lock
  • Logging of offline accesses: Access list in the lock with 1,000 entries (overwritten on a rolling basis, WO Legacy 250)
  • Access list readable with SmartIntego tool and WaveNet or local programming device
  • No battery warnings
  • Exclusive management by integrator system

NOTE

notice

Whitelist for locking devices read on both sides

Locking devices with readers on both sides (FD or BL) only have a whitelist for both sides.