Measurement and calculation - SmartLocker AX

  1. Measure the distance between the inside of the door and the dead-bolt stop (A), e.g. with the depth rod of a caliper gauge.
  2. Measure the thickness of the door/door panel (B).
  3. Refer to the tables for the parts required from the scope of delivery (adapter plates, dead-bolt fixture, flange extensions and screw). Additional parts can be ordered (see manual).

Inner side of door up to dead-bolt stop (A)

Adapter plate P

(LL.PLATE5)

Dead-bolt fixture R

0.0 mm to 5.95 mm

None

4 (5.9 mm)

6.05 mm to 7.25 mm

None

3 (7.5 mm)

7.35 mm to 8.85 mm

None

2 (9.1 mm)

8.95 mm to 10.45 mm

None

1 (10.4 mm)

10.55 mm to 10.95 mm

5 mm

4 (5.9 mm)

11.05 mm to 12.25 mm

5 mm

3 (7.5 mm)

12.35 mm to 13.85 mm

5 mm

2 (9.1 mm)

13.95 mm to 15.45 mm

5 mm

1 (10.4 mm)

15.55 mm to 15.95 mm

2 × 5 mm

4 (5.9 mm)

16.05 mm to 17.25 mm

2 × 5 mm

3 (7.5 mm)

17.35 mm to 18.85 mm

2 × 5 mm

2 (9.1 mm)

18.95 mm to 20.45 mm

2 × 5 mm

1 (10.4 mm)

20.55 mm to 20.95 mm

3 × 5 mm

4 (5.9 mm)

21.05 mm to 22.25 mm

3 × 5 mm

3 (7.5 mm)

22.35 mm to 23.85 mm

3 × 5 mm

2 (9.1 mm)

23.95 mm to 25.45 mm

3 × 5 mm

1 (10.4 mm)

Dead-bolt fixtures are numbered:

Door/door panel thickness B+ adapter plates P

Flange extensions F

Screw

10 mm to 16.0 mm

None

M4×16 mm

16.1 mm to 19.0 mm

M4×20 mm

19.1 mm to 25.0 mm

M4×25 mm

25.1 mm to 30 mm

M4×30 mm