Prerequisites - Locking cylinder (Z4) DoorMonitoring

The DM Cylinder imposes the following minimum requirements for the locking system and LSM:

  • LSM 3.2 SP1 Basic, Business or Professional installed
  • G2 or G2+G1 locking system
  • The software LSM.Business with the modules LSM Online and LSM Network xx (128 or Enterprise) is required for an online connection (tasks and responses/events) to the DM Cylinder

The appropriate software modules and hardware components must be installed to ensure door statuses in LSM can be further processed. They define key events in the locking system and the action required. The person responsible is thus informed by email if a fire door stays open too long, for example.

  • LSM Business
  • LSM NETWORK xx
  • LSM ONLINE
  • WaveNet components (router and network covers)

Different functions are available, depending on the configuration:

DM Cylinders in different locking systems

 

Offline

Online in LSM Basic

Online in LSM Business

Tracking to identify who last locked/unlocked a door

Upload access list with SmartCD

Access list with SmartCD and WaveNet

Access list with SmartCD and WaveNet

Door status monitoring

No

Yes/display in LSM

Yes/display in LSM

Transmission of alarms to the matrix

No

Yes. Display in matrix when LSM is open.

Yes. Display in matrix configuration of events and tasks

Generate events, such as a pop-up window

No

No

Yes

Incorporate lock with profile cylinder profile

Yes

Yes

Yes

Monitoring of an SLP* lock

No

No

Yes (with restrictions)

*SLP: self-locking panic lock