Prerequisites - Locking cylinder (Z4) DoorMonitoring
The DM Cylinder imposes the following minimum requirements for the locking system and LSM:
- LSM 3.2 SP1 Basic, Business or Professional installed
- G2 or G2+G1 locking system
- The software LSM.Business with the modules LSM Online and LSM Network xx (128 or Enterprise) is required for an online connection (tasks and responses/events) to the DM Cylinder
The appropriate software modules and hardware components must be installed to ensure door statuses in LSM can be further processed. They define key events in the locking system and the action required. The person responsible is thus informed by email if a fire door stays open too long, for example.
- LSM Business
- LSM NETWORK xx
- LSM ONLINE
- WaveNet components (router and network covers)
Different functions are available, depending on the configuration:
|
|
Offline |
Online in LSM Basic |
Online in LSM Business |
|---|---|---|---|
|
Tracking to identify who last locked/unlocked a door |
Upload access list with SmartCD |
Access list with SmartCD and WaveNet |
Access list with SmartCD and WaveNet |
|
Door status monitoring |
No |
Yes/display in LSM |
Yes/display in LSM |
|
Transmission of alarms to the matrix |
No |
Yes. Display in matrix when LSM is open. |
Yes. Display in matrix configuration of events and tasks |
|
Generate events, such as a pop-up window |
No |
No |
Yes |
|
Incorporate lock with profile cylinder profile |
Yes |
Yes |
Yes |
|
Monitoring of an SLP* lock |
No |
No |
Yes (with restrictions) |
*SLP: self-locking panic lock