Battery warnings - Locking cylinder (Z4) 3061
A battery management system has been implemented in locking cylinders and transponders which warns the user in good time that the battery capacity is diminished. This prevents the batteries from becoming fully discharged. The individual battery warning levels are described below.
The locking cylinder batteries feature a redundant system. If one of the batteries fails or its capacity falls below a certain level, the system emits a battery warning.
The battery warning levels between G1 and G2 differ after Battery Warning Level 2 if the battery capacity falls under the emergency battery warning threshold values.
| |
|
|
NOTE
After using a "G2 battery replacement medium" on locking devices, change the batteries immediately. Otherwise, the locking device may fail completely due to empty batteries.
WARNING LEVEL 1 | WARNING LEVEL 2 | FREEZE MODE | |
Active cylinder: | 8 short audible signals before engaging | Eight short audible signals 30 seconds long with one second pause each time before engaging | 6 audible signals (long – pause – short) |
Up to 15,000 access events or up to 9 months on standby | Up to 50 access events or up to 30 days | Battery replacement: activate with battery replacement transponder | |
Cylinder SC (transponder use): | 8 short audible signals before engaging | Eight short audible signals 30 seconds long with one second pause each time before engaging | 6 audible signals (long – pause – short) |
Cylinder SC (SmartCard use): | LED flashes red briefly 8 times before engaging | LED flashes red briefly twice for 30 seconds before engaging | LED flashes red once and blue once |
Up to 300 access events or up to 30 days | Up to 200 access events or up to 20 days | Battery replacement: activate with battery replacement transponder |