Storage mode (G1) - Locking cylinder (Z4) 3061
If the locking cylinder is in emergency battery storage mode, proceed as follows to open the door to change the battery and reset the cylinder.
- Take notebook or PDA (import locking plan beforehand) and programming device to the door in question.
- Select the corresponding lock from the locking plan.
- Re-programme locking cylinder without making any modifications. This eliminates the battery warning and storage mode.
- Engage the locking cylinder using an authorised transponder and open the door. The cylinder will immediately revert to storage mode, as both batteries are almost empty.
- Renew batteries (see below).
- Re-programme locking cylinder without making any modifications. This eliminates the battery warning check marks and storage mode.
- Engage the locking cylinder using an authorised transponder.
After battery replacement, the locking cylinder signals Warning Level 2 again. The locking cylinder's electronics then detect that the batteries are fully charged or have been replaced and the cylinder is available for normal use again.