General instructions - Locking cylinder (Z4) 3061
When installing the digital Locking Cylinder 3061, ensure that there are no sources of low-frequency radio interference in the surrounding area.
The profile cylinder housing should be fitted flush in outside areas; it should project a maximum of 3 mm and a profile cylinder escutcheon or security fitting should be installed if necessary. It is also important to ensure that no water is able to penetrate the cylinder via the cam section.
You must not strike the thumb-turns when installing the cylinder.
All thumb-turns are locked into place with a bayonet mount (exception: anti-panic inside knob and SKG/VdS outside knob).
The inner side of the Locking Cylinder 3061 is laser-engraved with (the letters IL for inside length) on the profile cylinder housing; the electronics side is identifiable by the black plastic ring between the thumb-turn and the profile cylinder housing.
Batteries are already installed before delivery.
All the tasks listed in this section can also be carried out using the installation/battery key.