Audible signals - MobileKey Locking cylinder (Z4) DoorMonitoring
|
Signal type |
Meaning |
Action required |
|---|---|---|
|
2 short audible signals before engaging and a short tone after disengaging |
Normal activation |
No |
|
1 short audible signal: cylinder does not engage. |
Attempted entry with a transponder listed in the locking system, but: booked outside the time zone: no authorisation, cylinder is deactivated |
Check authorisations. Read locking device, check status. Check time zone plan |
|
8 short audible signals before engaging: Battery Warning Level 1 |
Batteries are low |
Replace batteries in the cylinder |
|
8 short audible signals 30 seconds long with one second pause each time before engaging: Battery Warning Level 2 |
Batteries are almost completely empty |
Replace batteries in the cylinder immediately. |
|
6 audible signals (long – pause – short): Freeze mode |
Battery empty. Cylinder can no longer be opened using an authorised transponder. |
Replace batteries and reset with a battery replacement transponder. |
|
8 short audible signals after thumb-turn disengages |
Transponder battery is low |
Have transponder battery replaced |