Technical specifications - MobileKey Locking cylinder (Z4) DoorMonitoring
Cylinder model | Euro Profile DoorMonitoring Cylinder as per DIN 18252/EN1303, stainless steel, freely rotating on both sides |
Protocol generations | G2 or MobileKey |
Thumb-Turn diameter | 30 mm |
Basic installation length | 30-35 mm (external/internal dimension) |
Protection rating | IP54 (when installed) / .WP variant: IP66 |
Air humidity: | < 95%; non-condensing |
Battery type | 2 x Lithium CR2450 3V (Duracell, GP Batteries (Gold Peak), Murata, Panasonic) Batteries coated with bitter substances are not suitable. |
Temperature range | Operational: -25 °C to +65 °C |
Access memory | About 1,000 door statuses can be stored |
Time zone groups | 100+1 (time zone groups are not supported in MobileKey) |
Number of transponders per locking cylinder | Up to 64,000 or 100 for MobileKey |
Networking | Network-ready with integrated LockNode (Network Thumb-Turn Cover WNM.LN.I) |
Radio emissions
24.50 kHz - 25.06 kHz | -20 dBµA/m (10 m distance) |
868.000 MHz - 868.600 MHz / 869.700 MHz - 870.000 MHz Only for item numbers: MK.Z4.*LN*, MK.Z4.*DM* | <25 mW ERP |