Connections - RouterNode 2

NOTE

notice

IO connector only for RouterNode 2

You can only use the connectors of the IO connector at RouterNode 2.

Connection

Meaning

DC In

Pin connector

Power supply with round plug connector

IO-Vout

Terminal block: GND

Auxiliary voltage output - Earth connection

Terminal block: +3.3 V

Auxiliary voltage output - Positive pole

RJ45

Network connection

ANT

Connector for external antenna (see Antenna)

Connection

Meaning

Analogue input

Connection of an analogue signal from 0 VDC to 2.5 VDC.

Unused

Unused.

DI 3

The connection of a digital signal from 0 VDC to 3.3 VDC.

DI 2

The connection of a digital signal from 0 VDC to 3.3 VDC.

DI 1

The connection of a digital signal from 0 VDC to 3.3 VDC.

O3

Open drain output (for details, see IO connector und Technical specifications).

O2

Open drain output (for details, see IO connector und Technical specifications).

O1.NC

Potential-free relay output: Normally Closed (NC). This output is electrically connected to output 01.COM in the idle state.

O1.NO

Potential-free relay output: Normally Open (NO). This output is electrically connected to output 01.COM when energised.

O1.COM

Potential-free relay output: Common (COM). This output is either connected to output 01.NC or 01.NO, depending on the switching state of the relay.