Connections - Control device AX

Operating cable

Cable

Function

Black (connector 7)

GND (earth)

Red (connector 6)

VDD (supply voltage)

Green (connector 5)

Function input

Blue (connector 4)

Function input

Purple (connector 3)

Function input

Grey (connector 2)

Function input

White (connector 1)

Reference potential (for potential-free switching with button/relay)

The function inputs can be freely assigned in LSM.

The following actions are available:

Action

Meaning

Opening

Operates the locking device like a regular identification medium. You can select the name to be displayed for this entry in the access list.

Emergency release

Operates the locking device permanently. Ended by End of emergency release / emergency opening or a remote opening.

Only in pairs with End of emergency release / emergency opening.

Uses special transponder ID: 1.

End of emergency release / emergency opening

Ends the Emergency release.

Only in pairs with Emergency release

Uses special transponder ID: 0.

Deactivation

Deactivates the locking device (= all identification media are rejected). Terminated by:

  • Activation
  • Activation transponder or activation card
  • Programming device and Activate lock

Remote opening is also possible when the locking device is deactivated.

Uses special transponder ID: 3.

Activation

Activates the locking device (=normal state).

Uses special transponder ID: 5.

The reference potential is not a permanently applied voltage, but a pulsed auxiliary voltage (every 250 ms for a few ms). It is therefore only suitable for connecting buttons to the function inputs.

External battery pack (SV-CTD-AX.BAT)

The external battery pack allows the Control Device AX to be operated independently, e.g. via a flush-mounted socket. An external power supply is not necessary.

The battery pack is not compatible with the housing of the surface-mounted variant (‘COVER’).

When using your own battery solution with an external power supply, please note the minimum battery rating of: 2.36 Ah at 3 VDC.