SI offline battery warning - SmartIntego Locking cylinder (Z4)

This offline function is expected to be available from 2016.

  • Warning Level 1:
  • Low batteries: 8 short audible signals + LED flashes red briefly 8 times before engaging. Batteries will soon be empty. Replace batteries in the SmartHandle.
  • Warning Level 2:
  • Extremely low batteries: 8 short audible signals 30 seconds long + LED flashes red twice briefly with one second pause between each one during 30 seconds Emergency battery warning: batteries are almost completely empty. Replace the batteries in the SI-Locking Cylinder immediately.
  • Once Warning Level 2 has been emitted for the first time, the cylinder can be opened a maximum of 50 more times.
  • After reaching this number of opening operations or after about 4 weeks, the SI-Locking Cylinder automatically switches to freeze mode. Once at this warning level, SmartHandle can now only be activated using a battery replacement card and an authorised ID medium (to open the door + replace the batteries). Once the batteries are replaced, the SI-Locking Cylinder needs to read the battery replacement card again.

You need to add/programme a valid card associated with the locking system concerned. This is a special card which eliminates 'Freeze mode' on the locking device. An authorised ID medium is always required when you wish to open the door and replace the battery. You need to have programmed this special card with the T-ID 7. T-ID 7 is a special system ID, which the system integrator must create.