SI online battery warning - SmartIntego Locking cylinder (Z4)
- Online via the system
- In SmartIntego Online, a low battery status is signalled to the system by a designated bit when a booking (locking device event or 'Get status') is made. The system integrator must take this bit into account – by creating suitable warnings, for example – to prevent SI-Locking Cylinder from discharging completely.
- It can take up to 24 hours before the SI-Locking Cylinder resets the battery warning after a battery replacement.
- On site at the locking device
- It is also possible to use the SmartIntego tool to programme a battery replacement card. If you hold this card up to the card reader on the locking device, an internal resistance test is performed immediately, serving as a battery test. The warning on the locking device is immediately reset if the batteries have been replaced after a battery warning and a battery replacement card is used to complete an internal resistance test on the locking device concerned.
- In this case, no freeze mode or escalation levels are created, only information transmitted by the 'Event' or 'GetStatus' (such as a warning or alarm), which the ACP needs to evaluate.